Product details



OVERVIEW

Rated Power (KW/KVA)Standby Power(KW/KVA)Engine ModelCylindersBore*Trip(mm)Fuel Consumption(g/kw.h)
74/9383/104TAD530GE4108/130≤213
88/11098/123TAD531GE4108/130≤218
112/140115/144TAD532GE4108/130≤214
133/166148/185TAD731GE6108/130≤215
160/200179/224TAD732GE6108/130≤213
175/219195/244TAD733GE6108/130≤216
213/266238/298TAD734GE6108/130≤204
271/339298/373TAD1341GE6131/158≤191
303/379333/416TAD1342GE6131/158≤191
325/406356/445TAD1343GE6131/158≤192
354/443389/486TAD1344GE6131/158≤194
388/485431/539TAD1345GE6131/158≤196
430/538473/591TAD1641GE6144/165≤199
503/629554/692TAD1642GE6144/165≤198
536/670596/745TWD1643GE6144/165≤199

Note: Specifications based on 1500RPM, 50HZ, 230/400V, power factor 0.8, 3 phase 4 wire system. 60HZ generator set can be customized


Volvo Diesel Genset Features

1.Volvo diesel generator sets have high load-bearing capacity , fast and reliable cold start performance; 

2.stable operation, low exhaust , low operating costs, and compact appearance; 

3.Volvo engines can reach the promise of 30,000 hours trouble-free running. 

4.Small volume;

5.Good performance in high altitude areas   


Quality & Testing

Production & management follow ISO9001:2015 requirement, each generator must be passed strict inspection in each progressing.

1. All the raw materials/parts by IQC (Incoming Quality Control) before launch into process.

  2. Each generator/part under control of IPQC (Input Process Quality Control).

  3. Each generator/part must be pass 100% inspection between process.

  4. All-sided ex-factory testing in various condition (Outgoing Quality Control), test items as following.

>Loading test in 0%, 25%, 50%, 75%, 100%,

>Heat run test

>Insulation resistance test

>Frequently starting test

>Alarm and timing relays test.

Packing & Delivery

User Evaluation
Inquire Now

If you have any questions or needs about the product, please fill in the following form and we will contact you as soon as possible.